Choose hardware and build¶
On this page: a step-by-step decision for one pool, a summary table, and what is not available yet. Decide per pool; a partner can use different boards and builds for different pools. An interactive version of this guide will follow.
Step 1: what should Lutra do at this pool?¶
What does the pool maintainer want? Pick the card that fits.
Goal
Also switch equipment from Lutra: pump speed, filter pump, backwash valve, heating enable, refill valve, light, aux.
Switching build
- 8DI-8DO board only
- Interposing relays or contactors
- An electrician, see step 4
Goal
Dose chemicals (pH, chlorine).
Not available yet
- Monitor now with the read build
Situation
The equipment is not supported by Lutra firmware, or the pool already has its own controller or PLC with network access.
External devices API
- No Lutra box needed
- PLC: see Connecting a PLC
- Read build: reads the bus and the inputs, sends readings, never switches an output. It contains no code that can switch an output. See Builds.
- Switching build: everything the read build does, plus outputs with interlocks, schedules and limits in the firmware. Only for the 8DI-8DO board. See Switching build.
- External devices API: your own device sends readings over MQTT or HTTPS. See External devices; for a pool that already runs its own PLC, see Connecting a PLC.
To be confirmed
Dosing (pH and chlorine) is being explored as a separate build with hardware interlocks and is not available. The switching build deliberately excludes dosing and pool cover movement. Do not use the switching build to drive dosing pumps.
Step 2: how does the box reach the internet?¶
| Situation | Board |
|---|---|
| Network cable available, or PoE wanted (one cable for data and power) | ESP32-S3-POE-ETH-8DI-8DO |
| Only Wi-Fi in the plant room | Either board; the RS485-CAN board is Wi-Fi only |
| No usable network at all | A 4G/5G router next to the box (neither board has a modem) |
See Boards and Network. Another ESP32-S3 board in mind? Lutra is open to adding boards; see New boards.
Step 3: what has to be read?¶
| What | Needs | Notes |
|---|---|---|
| Controllers, chlorinators, pumps, heat pumps with Modbus RTU | RS485 on either board | Check the supported devices. All devices on one bus need the same baud rate, parity and stop bits. |
| A bus that already has a master (PLC, panel) | Listen-only mode | Lutra must never be a second master on such a bus. See Bus devices and inputs. |
| Contacts: flow switch, pump running, level floats, leak, plant room door | Digital inputs (DI) | Only the 8DI-8DO board has inputs. |
| Wireless sensors: pool thermometer, plant room temperature and humidity, leak, door | Bluetooth, BTHome v2, unencrypted, fixed address; firmware 0.5.0 or later, either board | Passive, read only. Not yet tested with a real sensor. See Bluetooth sensors. |
| Own pH/ORP probes | A Modbus pH/ORP transmitter and a flow cell with flow switch | See Own probes and flow cell. |
| Equipment only reachable through the manufacturer's cloud | Not on the box | Cloud connectors in the backend are being designed. |
To be confirmed
How a flow switch is read on the RS485-CAN board (it has no digital inputs) is an open question.
Step 4: who installs what?¶
| Choice | Lutra box wiring (low voltage) | Electrician needed |
|---|---|---|
| Read build, bus only | Installer or technician | For the box's power supply if it is mains-fed. See Electrical installation and safety. |
| Read build with DI contacts | Installer or technician | If a contact comes from a contactor or device that also carries mains, the auxiliary contact wiring must be done safely; see the safety chapter. |
| Switching build | Installer for the low-voltage side | Yes: interposing relays, contactors, all mains wiring and the hardware interlocks. |
Summary¶
| The pool maintainer wants | Board | Build | Extra hardware |
|---|---|---|---|
| Monitor, network by cable or PoE | 8DI-8DO | Read | none |
| Monitor, Wi-Fi only, no contacts | 8DI-8DO or RS485-CAN | Read | none |
| Monitor plus contacts (flow, pump running, levels) | 8DI-8DO | Read | contacts on DI |
| Monitor with own probes | 8DI-8DO | Read | pH/ORP transmitter, flow cell, flow switch |
| Switch pump, valves, heating, light | 8DI-8DO | Switching | interposing relays or contactors, hardware interlocks, electrician |
| Dosing | (not available) | (not available) | |
| Unsupported device or own controller | none | none | device with TLS client certificate support |
Changing the build later is possible, but only by a complete reflash over USB on site, never by a remote update. See Converting to another build.
Related pages¶
Last reviewed: 2026-11-24. Applies to Lutra Lite 0.5.0.