Skip to content

Choose hardware and build

On this page: a step-by-step decision for one pool, a summary table, and what is not available yet. Decide per pool; a partner can use different boards and builds for different pools. An interactive version of this guide will follow.

Step 1: what should Lutra do at this pool?

What does the pool maintainer want? Pick the card that fits.

Goal

Only see readings and alerts (monitor).

Read build

  • Either board
  • Continue with step 2

Goal

Also switch equipment from Lutra: pump speed, filter pump, backwash valve, heating enable, refill valve, light, aux.

Switching build

  • 8DI-8DO board only
  • Interposing relays or contactors
  • An electrician, see step 4

Goal

Dose chemicals (pH, chlorine).

Not available yet

  • Monitor now with the read build

Situation

The equipment is not supported by Lutra firmware, or the pool already has its own controller or PLC with network access.

External devices API

  • Read build: reads the bus and the inputs, sends readings, never switches an output. It contains no code that can switch an output. See Builds.
  • Switching build: everything the read build does, plus outputs with interlocks, schedules and limits in the firmware. Only for the 8DI-8DO board. See Switching build.
  • External devices API: your own device sends readings over MQTT or HTTPS. See External devices; for a pool that already runs its own PLC, see Connecting a PLC.

To be confirmed

Dosing (pH and chlorine) is being explored as a separate build with hardware interlocks and is not available. The switching build deliberately excludes dosing and pool cover movement. Do not use the switching build to drive dosing pumps.

Step 2: how does the box reach the internet?

Situation Board
Network cable available, or PoE wanted (one cable for data and power) ESP32-S3-POE-ETH-8DI-8DO
Only Wi-Fi in the plant room Either board; the RS485-CAN board is Wi-Fi only
No usable network at all A 4G/5G router next to the box (neither board has a modem)

See Boards and Network. Another ESP32-S3 board in mind? Lutra is open to adding boards; see New boards.

Step 3: what has to be read?

What Needs Notes
Controllers, chlorinators, pumps, heat pumps with Modbus RTU RS485 on either board Check the supported devices. All devices on one bus need the same baud rate, parity and stop bits.
A bus that already has a master (PLC, panel) Listen-only mode Lutra must never be a second master on such a bus. See Bus devices and inputs.
Contacts: flow switch, pump running, level floats, leak, plant room door Digital inputs (DI) Only the 8DI-8DO board has inputs.
Wireless sensors: pool thermometer, plant room temperature and humidity, leak, door Bluetooth, BTHome v2, unencrypted, fixed address; firmware 0.5.0 or later, either board Passive, read only. Not yet tested with a real sensor. See Bluetooth sensors.
Own pH/ORP probes A Modbus pH/ORP transmitter and a flow cell with flow switch See Own probes and flow cell.
Equipment only reachable through the manufacturer's cloud Not on the box Cloud connectors in the backend are being designed.

To be confirmed

How a flow switch is read on the RS485-CAN board (it has no digital inputs) is an open question.

Step 4: who installs what?

Choice Lutra box wiring (low voltage) Electrician needed
Read build, bus only Installer or technician For the box's power supply if it is mains-fed. See Electrical installation and safety.
Read build with DI contacts Installer or technician If a contact comes from a contactor or device that also carries mains, the auxiliary contact wiring must be done safely; see the safety chapter.
Switching build Installer for the low-voltage side Yes: interposing relays, contactors, all mains wiring and the hardware interlocks.

Summary

The pool maintainer wants Board Build Extra hardware
Monitor, network by cable or PoE 8DI-8DO Read none
Monitor, Wi-Fi only, no contacts 8DI-8DO or RS485-CAN Read none
Monitor plus contacts (flow, pump running, levels) 8DI-8DO Read contacts on DI
Monitor with own probes 8DI-8DO Read pH/ORP transmitter, flow cell, flow switch
Switch pump, valves, heating, light 8DI-8DO Switching interposing relays or contactors, hardware interlocks, electrician
Dosing (not available) (not available)
Unsupported device or own controller none none device with TLS client certificate support

Changing the build later is possible, but only by a complete reflash over USB on site, never by a remote update. See Converting to another build.

Last reviewed: 2026-11-24. Applies to Lutra Lite 0.5.0.