Own probes and flow cell¶
On this page: the measuring kit for pools whose equipment cannot be read or lacks sensors, the hydraulic installation of the flow cell, temperature options, and calibration. The measuring kit only measures; dosing is not available.
The measuring kit¶
| Part | What |
|---|---|
| Controller | Lutra Lite on the 8DI-8DO board, Modbus master on RS485 |
| pH and ORP | Two isolated pH/ORP transmitters with RS485 Modbus, each with its own address |
| Temperature | Preferably a PT1000 in the flow cell on the temperature (ATC) input of the pH transmitter, read over Modbus. Alternatives: a probe with built-in PT1000/NTC10K, or a DS18B20 sensor (not on a DI) |
| Flow | A flow switch in the flow cell, on a digital input |
| Enclosure | IP65, optionally with conformal coating |
Supported transmitter profiles are listed in Supported devices (ComWinTop pH and ORP transmitters, and Lutra's own pH/ORP module, all as draft).
To be confirmed
- Lutra's own pH/ORP module is in design and not available yet.
- The choice of probe and transmitter suppliers is still being tested for drift over 1 to 2 months.
- What exactly is supplied in a kit is not fixed.
Hydraulic installation¶
- Flow cell mounted on the wall, on a bypass: two tapping saddles, ball valves and the flow switch.
- Probes after the filter and before the heating, mounted upright.
- Injection points (for future dosing) after the heating.
- Saddles for 50 mm pipe as standard, 63 mm as an option.
Flow and validity¶
Without flow through the cell, probe readings are marked invalid (kept, not discarded). After flow returns there is a 60 second run-in. See Flow switch.
Calibration¶
- pH is calibrated at two points with buffer solutions; ORP gets an offset.
- Calibration is done on site only, never through the cloud.
To be confirmed
The calibration procedure for installers (on which device, which buffers, via the setup page or the USB console) is not fixed yet.
Chlorine with stabiliser¶
If the pool uses trichlor (with stabiliser, CYA), ORP says little about free chlorine. Rely mainly on pH and a measured free chlorine value.
Related pages¶
Last reviewed: 2026-11-24. Applies to Lutra Lite 0.4.1.