Troubleshooting¶
On this page: symptoms and what to check, grouped by area, plus the diagnosis tools you can use on site and remotely.
First look¶
- Look at the LED (8DI-8DO). See LED and BOOT button.
- Open the setup page (BOOT 3 seconds) and read Status and Logs. See Setup page.
- In the portal, open the pool and check "last seen" for the box. See Remote panel.
No network¶
| Symptom | Check |
|---|---|
| LED yellow, double blink for a long time | The box keeps trying to connect. Open the setup page; the status shows the reason. |
| "Password refused" | Re-enter the Wi-Fi password (case sensitive; tap the eye to check). |
| "Network not found" | Wi-Fi out of range or hidden network name mistyped. Check the antenna (U.FL on the 8DI-8DO). Consider a network cable. |
| "No address" | The router gave no DHCP address. Check the router or cable. |
| "No internet" / LED orange | Network works but the cloud is unreachable. Check that outgoing connections are allowed; see Network. |
| Network cable not used | Setup page shows "no network cable": check the cable and the switch port. Cable is available on the 8DI-8DO board only. |
If nothing helps: factory reset (BOOT 10 to 30 seconds). Network and settings are cleared; identity and pairing code stay. See What a factory reset clears.
No readings¶
| Symptom | Check |
|---|---|
| Device status "no answer" | A and B wiring, device address, baud rate and parity, termination. See Wiring the box. |
| Check on the setup page shows nothing | Use the bus scan to find the address. Make sure the device's bus parameters match its profile. |
| Some devices answer, others not | All devices on one bus need the same baud rate, parity and stop bits. See Bus devices and inputs. |
Readings marked no_flow |
No flow through the measuring cell; expected when the pump is off. |
Readings marked unknown |
No flow switch and the device does not report flow; flow-dependent values are not counted. |
| The bus is silent | No device list saved, mode set to "Off", or the box is in safe mode. |
| Tiles in the portal show "old" | No new reading for more than one hour. |
| Alert "box no longer reporting" | No message for 30 minutes. Check power and internet. |
To be confirmed
A fixed checklist for bus faults (A and B swapped, wrong address, termination) and the exact meaning of the status "communication error" are still to be written.
Updates¶
| Symptom | Meaning |
|---|---|
other build / other board |
The image is for another channel. See Builds. |
no build id |
The image is from before build identities existed. Use a current image. |
| Version refused | Only newer versions; a version that rolled back on this box is refused permanently. |
| Signature refused | The image is not signed by Lutra or was damaged. |
| Same version after the update | The new version failed its self-test and rolled back. Read the log. |
| Remote update does not start | Remote updates install between 02:00 and 05:00 local time and need a valid clock. |
Safe mode¶
After 5 abnormal restarts in a row the box starts in safe mode: network, setup page and updates work, the bus does not run. The status page shows Safe mode and the list of last restarts. Install a fixed version; a deliberate restart resets the series. See LED and BOOT button.
Diagnosis tools¶
| Tool | Where | Who |
|---|---|---|
| Status and log on the setup page | On site, temporary network | Anyone with physical access |
USB console (status, di, tz, interval, remote on) |
On site, USB-C cable | Technician |
get_diag (diagnosis) |
Remote, Remote panel | Administrator, technician |
get_logs (last log lines, firmware 0.2.5 and later) |
Remote | Administrator, technician |
busscan |
Remote, at most once per hour | Administrator, technician |
The log never contains passwords, keys, tokens, certificates or download links.
Related pages¶
Last reviewed: 2026-11-24. Applies to Lutra Lite 0.4.1.