Skip to content

Troubleshooting

On this page: symptoms and what to check, grouped by area, plus the diagnosis tools you can use on site and remotely.

First look

  1. Look at the LED (8DI-8DO). See LED and BOOT button.
  2. Open the setup page (BOOT 3 seconds) and read Status and Logs. See Setup page.
  3. In the portal, open the pool and check "last seen" for the box. See Remote panel.

No network

Symptom Check
LED yellow, double blink for a long time The box keeps trying to connect. Open the setup page; the status shows the reason.
"Password refused" Re-enter the Wi-Fi password (case sensitive; tap the eye to check).
"Network not found" Wi-Fi out of range or hidden network name mistyped. Check the antenna (U.FL on the 8DI-8DO). Consider a network cable.
"No address" The router gave no DHCP address. Check the router or cable.
"No internet" / LED orange Network works but the cloud is unreachable. Check that outgoing connections are allowed; see Network.
Network cable not used Setup page shows "no network cable": check the cable and the switch port. Cable is available on the 8DI-8DO board only.

If nothing helps: factory reset (BOOT 10 to 30 seconds). Network and settings are cleared; identity and pairing code stay. See What a factory reset clears.

No readings

Symptom Check
Device status "no answer" A and B wiring, device address, baud rate and parity, termination. See Wiring the box.
Check on the setup page shows nothing Use the bus scan to find the address. Make sure the device's bus parameters match its profile.
Some devices answer, others not All devices on one bus need the same baud rate, parity and stop bits. See Bus devices and inputs.
Readings marked no_flow No flow through the measuring cell; expected when the pump is off.
Readings marked unknown No flow switch and the device does not report flow; flow-dependent values are not counted.
The bus is silent No device list saved, mode set to "Off", or the box is in safe mode.
Tiles in the portal show "old" No new reading for more than one hour.
Alert "box no longer reporting" No message for 30 minutes. Check power and internet.

To be confirmed

A fixed checklist for bus faults (A and B swapped, wrong address, termination) and the exact meaning of the status "communication error" are still to be written.

Updates

Symptom Meaning
other build / other board The image is for another channel. See Builds.
no build id The image is from before build identities existed. Use a current image.
Version refused Only newer versions; a version that rolled back on this box is refused permanently.
Signature refused The image is not signed by Lutra or was damaged.
Same version after the update The new version failed its self-test and rolled back. Read the log.
Remote update does not start Remote updates install between 02:00 and 05:00 local time and need a valid clock.

Safe mode

After 5 abnormal restarts in a row the box starts in safe mode: network, setup page and updates work, the bus does not run. The status page shows Safe mode and the list of last restarts. Install a fixed version; a deliberate restart resets the series. See LED and BOOT button.

Diagnosis tools

Tool Where Who
Status and log on the setup page On site, temporary network Anyone with physical access
USB console (status, di, tz, interval, remote on) On site, USB-C cable Technician
get_diag (diagnosis) Remote, Remote panel Administrator, technician
get_logs (last log lines, firmware 0.2.5 and later) Remote Administrator, technician
busscan Remote, at most once per hour Administrator, technician

The log never contains passwords, keys, tokens, certificates or download links.

Last reviewed: 2026-11-24. Applies to Lutra Lite 0.4.1.