Skip to content

PoolLab via LabCOM

PoolLab and PrimeLab photometers from Water-i.d. sync their tests to the LabCOM cloud. With this connection Lutra fetches those tests and files them under the right pool as manual tests, marked PoolLab via LabCOM. They show up in the pool's chart and test list, and cyanuric acid and alkalinity update the water profile.

The connection is beta: Water-i.d. does not publish official API documentation. Lutra only reads.

1. Get the API token

  1. Log in at labcom.cloud.
  2. Go to Profile > Settings > GraphQL API (direct link).
  3. Copy the token.

The token gives access to everything in that LabCOM account, including writing. Lutra never writes, but it is good practice to use a separate LabCOM account for Lutra and share your sampling points with it, if your LabCOM setup allows that. If the token was ever shared by mistake, renew it in LabCOM and replace it in Lutra.

2. Connect in Lutra

  1. In the portal go to Settings > API and integrations > Cloud connections.
  2. On LabCOM (PoolLab) choose Connect, paste the token and save.

Lutra stores the token encrypted and never shows it again. The card then shows when and by whom it was set, with Replace and Remove. Within 15 minutes the sampling points appear.

Lutra lists every LabCOM sampling point with its name, Identifier, place, volume and its most recent measurements. For each point choose:

  • an existing pool: Lutra suggests one when the point's Identifier matches the pool code (see below) or, less certain, when the names look alike;
  • New pool: Lutra creates a pool with the point's name and volume (no customer is created; link the pool to a customer yourself if you want);
  • Skip: leave the point out; you can still link it later.

Then choose Apply. For every linked point Lutra fetches the tests of the last 90 days, and from then on every new test.

Automatic matching with the Identifier

Each pool in Lutra has a short pool code: open the pool, Devices > Cloud connections. Enter that code in LabCOM in the Identifier field of the sampling point. Lutra then suggests that pool with certainty; you confirm with one click. Upper and lower case and spaces do not matter.

New customers later

  1. Create the sampling point in LabCOM itself (in the LabCOM app or on labcom.cloud; see LabCOM's own help for how). Lutra cannot create sampling points.
  2. Do a test with the PoolLab and let it sync.
  3. Within 15 minutes the point appears at the top of the list in Lutra as new, with that test. Link it to a pool or create a new pool from it, and choose Apply.

Tests of a point that is not linked are only shown in this list; they are filed under a pool once you link it.

What Lutra reads

Reads Does not read
Sampling points: name, Identifier, place, pool text, volume Street, postal code, phone, email, GPS, notes
Tests: parameter, value, unit, time, device serial number Name of the person who measured, comments

Tests Lutra does not recognise yet are skipped (not guessed) and counted, so we can add them. Lutra never writes to LabCOM.

Times and time zones

LabCOM stores the clock time of the photometer, not UTC. Lutra therefore reads test times as local time in the pool's time zone (the pool's Settings), including summer and winter time. If tests on a pool appear one or two hours off, switch Times are the pool's local time on the connection card.

Status and errors

  • Active: everything works; the card shows when Lutra last fetched.
  • Error: LabCOM did not answer or answered unexpectedly; Lutra retries with growing pauses.
  • Token refused: the token was revoked or renewed in LabCOM. Lutra stops and mails the administrators once. Choose Replace and paste the new token.

Unlinking and removing

  • Unlink a point: new tests no longer go to that pool. You choose whether tests already imported stay (default) or are deleted.
  • Remove the connection: Lutra deletes the token and all links. Imported tests stay on the pools unless you choose to delete them. Revoke the token in LabCOM as well; Lutra cannot do that.

Last reviewed: 2026-11-25. Applies to Lutra Lite 0.5.5.