Supported devices

On this page: the device profiles in the firmware and their status, the ways Lutra can reach equipment, and how a new device gets added.

Profile status

Status Meaning
verified Works in practice
draft Register map known from documentation or research, not yet tested on hardware
pending Waiting for information; cannot be read yet

Draft profiles

Whether a draft profile may be used at a client's pool, or only on test boxes, is not decided. Ask Lutra before relying on a draft profile.

Profiles

Make Model Connection Status
AstralPool (Fluidra) Elite Connect salt chlorinator Modbus RTU verified
Aquagem (Hyper Pool Group) InverCaptain inverter pump Modbus RTU verified
AstralPool (Fluidra) Control Basic Plus pH or Rx (dosing pump with control) Modbus RTU draft
Sugar Valley (Hayward) NeoPool platform: Hidrolife, Oxilife, Aquascenic, Bionet and others; OEM Hayward AquaRite+ (SV), AquaRite HC LS, Bayrol, Brilix, Kripsol and others Modbus RTU draft
Pahlén Autodos M1/M2/M3 measuring and dosing controller with Modbus board Modbus RTU draft
Fairland (OEM) Inverter heat pump with board MWH216/MWH298 (IPS Pro, IPS 170, InverX, IPHCR) Modbus RTU draft
PHNIX (OEM) Heat pump controller PC1004, port CN13 (for example Gullberg & Jansson MELIUS 90) Modbus RTU draft
PHNIX (OEM) Heat pump controller PC1002, display bus (for example Gullberg & Jansson S series) Modbus RTU, listen only draft
Eletechsup R4DCB08, 8 channel DS18B20 temperature to Modbus Modbus RTU draft
ComWinTop (CWT) CWT-BL pH and temperature transmitter Modbus RTU draft
ComWinTop (CWT) CWT-BL ORP transmitter Modbus RTU draft
Lutra Pool pH/ORP/temperature module Modbus RTU draft (hardware in design)
Aseko ASIN AQUA NET, Home and Salt with firmware 7.x (binary frame) Binary frame draft (decoder only)
AstralPool (Fluidra) Control Connect All in One Modbus RTU pending
AstralPool (Fluidra) Clear Connect salt chlorinator unknown pending
AstralPool (Fluidra) Smart Next salt chlorinator unknown pending

The list is generated from the profiles in packages/devices/profiles of the Lutra repository; the firmware contains all profiles of the moment it was built.

Ways Lutra reaches equipment

Class Example Status
Modbus RTU, Lutra is master Most profiles above Built
Modbus RTU, listen only next to an existing master PLC, PHNIX PC1002 Decoding built; serial connection not finished
Fixed binary frames Aseko v7 Decoder built; transport not built
Own RS485 protocols (not Modbus) Pentair, Jandy/AquaLink, Hayward pump bus Later, per protocol
Modbus TCP, Lutra is client Devices with Ethernet Modbus Later
Local HTTP/JSON, Lutra is client Heat pumps and controllers with a local API Built, not tested on hardware
Contacts on DI Pump running, flow, alarms, levels Built
Contacts driven by DO Pump speeds, valves, enable signals Switching build only
Manufacturer clouds Fluidra Pool, iAquaLink and others Not on the box: cloud connectors in the backend, in design
Bluetooth (BLE), BTHome v2 sensors, passive Pool thermometers, temperature and humidity, leak and door sensors Built in 0.5.0, not yet tested with a real sensor. See Bluetooth sensors
Bluetooth (BLE), manufacturer protocols Some chlorinators and heat pumps Not supported (protocols undocumented)

Adding a new device

A device is added as a profile (data, not code) with automated tests. Installers cannot add profiles on site. If equipment is missing, ask Lutra. For equipment that can send its own readings, the external devices API is an alternative that works today.

To be confirmed

Delivering a single new or corrected profile to a box without a firmware update (a signed profile supplement) is decided in principle but not built.

Last reviewed: 2026-11-24. Applies to Lutra Lite 0.5.0.