Skip to content

Network

On this page: cable and Wi-Fi, what happens when a connection fails, which connections the box makes, how it keeps time, and how it buffers readings when offline.

Cable or Wi-Fi

A network cable is preferred. With PoE (802.3af) one cable carries data and power.

8DI-8DO board RS485-CAN board
Network cable (Ethernet, DHCP) yes no
Wi-Fi yes yes
4G/5G via an external router via an external router

On the 8DI-8DO board Ethernet is always on. When the cable has an address, the cable is used; when the cable is unplugged, Wi-Fi takes over (if Wi-Fi is configured). The setup page shows "Cable detected" or "no network cable".

Setting the network

On the setup page, as the last step:

  1. Choose Wi-Fi (from a scan list, or Join hidden network) and enter the password, or choose Network cable (8DI-8DO only, selectable only when the Ethernet link is up).
  2. Press Save & Connect. The box saves the settings and the page shows the LED legend.
  3. After a few seconds the temporary network switches off and the box connects, without a restart.
  4. If it cannot connect within 60 seconds, the temporary network opens again for 10 minutes and the page shows the reason: password refused, network not found, or no internet.

The network can always be changed on site with 3 seconds on BOOT, without the pairing code. It can never be changed remotely.

Wi-Fi rules: SSID up to 32 bytes; password empty (open network) or 8 to 63 printable ASCII characters. Passwords are case sensitive and never appear in a log.

Connections the box makes

The box only makes outgoing connections. It needs:

Purpose Destination Protocol
Cloud (readings, events, settings, commands) iot.lutrapool.com MQTT over TLS with client certificate, port 8883
Firmware updates fw.lutrapool.com HTTPS
Time pool.ntp.org, time.cloudflare.com SNTP (UDP 123)
Name resolution and address the local network DNS, DHCP

To be confirmed

A complete firewall list (ports and host names for strict networks) has not been published as a reference yet. Firmware older than 0.2.10 connects to the AWS IoT endpoint directly instead of iot.lutrapool.com.

Time

The box keeps time in UTC. At start-up it reads the battery-backed real-time clock, then corrects it through SNTP (and sets the RTC again every 6 hours or when it drifts more than 2 seconds). Local time, used for the night window of updates and for schedules in the switching build, comes from the time zone setting tz, which the cloud sets from the pool's location. Default UTC0 on a new box. See Remote commands and settings.

Offline buffer

Measuring and buffering never wait for the network.

  • Every message is first written to a flash buffer of about 9.7 MB and marked as sent only after the cloud acknowledges it. The buffer survives restarts and power loss.
  • After the connection returns, messages are sent one at a time, in order.
  • When the buffer is full, the oldest messages are dropped and counted (cloud_dropped on the status page).
  • How long the buffer lasts depends on the message size: about 60 days for a box without bus devices, about 8 days with one device of around twenty values (at one message per minute).

To be confirmed

The buffer durations above were calculated for one message per minute. Since 21 November 2026 the default interval is 300 seconds, which lengthens them; updated figures have not been published.

Last reviewed: 2026-11-24. Applies to Lutra Lite 0.4.1.