On this page: the fixed list of quantities that every source (Lutra boxes, external devices) delivers, and the statuses of a reading. Lutra never converts units on input: a value must be in the unit listed here.

A quantity is what a value means (for example orp), with a fixed unit. Devices deliver their own points (for example orp_mv); the cloud maps points to quantities through the device profile. The portal, alerts and reports work with quantities only, never with brands.

Catalogue

Generated from packages/devices/quantities.json in the Lutra repository.

Key Label Group Type Unit Range or values
ph pH water number pH 0 to 14
orp Redox (ORP) water number mV -1500 to 1500
free_cl Free chlorine water number mg/l 0 to 20
combined_cl Combined chlorine water number mg/l 0 to 20
salt Salt water number g/l 0 to 60
cya Cyanuric acid (stabiliser) water number mg/l 0 to 300
total_alkalinity Total alkalinity water number mg/l 0 to 500
calcium_hardness Calcium hardness water number mg/l 0 to 2000
water_temp Water temperature water number °C -5 to 60
flow Flow water bool
flow_rate Flow rate water number m3/h 0 to 500
level_low Level low water bool
level_fill Level refill water bool
level_high Level high water bool
ph_setpoint pH setpoint water number pH 0 to 14
orp_setpoint ORP setpoint water number mV -1500 to 1500
free_cl_setpoint Chlorine setpoint water number mg/l 0 to 20
water_temp_setpoint Water temperature setpoint water number °C 0 to 60
air_temp Air temperature air number °C -40 to 70
air_humidity Air humidity air number % 0 to 100
outdoor_temp Outdoor temperature air number °C -40 to 60
pump_running Filter pump equipment bool
pump_speed Pump speed equipment number % 0 to 100
filter_pressure Filter pressure equipment number kPa 0 to 1000
cover_state Cover equipment enum open, closed, moving, unknown
light Light equipment bool
backwash Backwash equipment bool
fill_valve Refill valve equipment bool
heater_on Heating equipment bool
heatpump_on Heat pump equipment bool
heatpump_mode Heat pump mode equipment enum heat, cool, auto
heatpump_water_in Heat pump water in equipment number °C -5 to 70
heatpump_water_out Heat pump water out equipment number °C -5 to 70
chlorinator_production Chlorinator production equipment number % 0 to 100
uv_on UV lamp equipment bool
plantroom_door Plant room door equipment enum open, closed
leak Leak equipment bool
fault Fault equipment bool
pump_power Pump power energy number W 0 to 10000
heatpump_power Heat pump power energy number W 0 to 50000
pump_energy Pump energy energy counter kWh 0 to 10000000
heat_energy Heat energy energy counter kWh 0 to 10000000

Some quantities accept an equivalent unit through a fixed factor in the catalogue (for example ppm for mg/l). A key is never renamed or reused. New quantities are added to the catalogue for everyone; ask Lutra.

Reading statuses

Status Meaning
ok Valid reading
out_of_range Outside the catalogue range; value kept
invalid The device reported a value that is not a valid measurement
no_flow No flow through the measuring cell; value not counted
comm_error Communication error with the device
no_answer The device did not answer
unknown Flow state unknown (no flow switch and the device does not report flow); value not counted

Two sources may deliver the same quantity for one pool; both are kept, and the cloud chooses per pool which one is shown first.