Quantities¶
On this page: the fixed list of quantities that every source (Lutra boxes, external devices) delivers, and the statuses of a reading. Lutra never converts units on input: a value must be in the unit listed here.
A quantity is what a value means (for example orp), with a fixed unit. Devices deliver their own points
(for example orp_mv); the cloud maps points to quantities through the device profile. The portal, alerts and
reports work with quantities only, never with brands.
Catalogue¶
Generated from packages/devices/quantities.json in the Lutra repository.
| Key | Label | Group | Type | Unit | Range or values |
|---|---|---|---|---|---|
ph |
pH | water | number | pH | 0 to 14 |
orp |
Redox (ORP) | water | number | mV | -1500 to 1500 |
free_cl |
Free chlorine | water | number | mg/l | 0 to 20 |
combined_cl |
Combined chlorine | water | number | mg/l | 0 to 20 |
salt |
Salt | water | number | g/l | 0 to 60 |
cya |
Cyanuric acid (stabiliser) | water | number | mg/l | 0 to 300 |
total_alkalinity |
Total alkalinity | water | number | mg/l | 0 to 500 |
calcium_hardness |
Calcium hardness | water | number | mg/l | 0 to 2000 |
water_temp |
Water temperature | water | number | °C | -5 to 60 |
flow |
Flow | water | bool | ||
flow_rate |
Flow rate | water | number | m3/h | 0 to 500 |
level_low |
Level low | water | bool | ||
level_fill |
Level refill | water | bool | ||
level_high |
Level high | water | bool | ||
ph_setpoint |
pH setpoint | water | number | pH | 0 to 14 |
orp_setpoint |
ORP setpoint | water | number | mV | -1500 to 1500 |
free_cl_setpoint |
Chlorine setpoint | water | number | mg/l | 0 to 20 |
water_temp_setpoint |
Water temperature setpoint | water | number | °C | 0 to 60 |
air_temp |
Air temperature | air | number | °C | -40 to 70 |
air_humidity |
Air humidity | air | number | % | 0 to 100 |
outdoor_temp |
Outdoor temperature | air | number | °C | -40 to 60 |
pump_running |
Filter pump | equipment | bool | ||
pump_speed |
Pump speed | equipment | number | % | 0 to 100 |
filter_pressure |
Filter pressure | equipment | number | kPa | 0 to 1000 |
cover_state |
Cover | equipment | enum | open, closed, moving, unknown |
|
light |
Light | equipment | bool | ||
backwash |
Backwash | equipment | bool | ||
fill_valve |
Refill valve | equipment | bool | ||
heater_on |
Heating | equipment | bool | ||
heatpump_on |
Heat pump | equipment | bool | ||
heatpump_mode |
Heat pump mode | equipment | enum | heat, cool, auto |
|
heatpump_water_in |
Heat pump water in | equipment | number | °C | -5 to 70 |
heatpump_water_out |
Heat pump water out | equipment | number | °C | -5 to 70 |
chlorinator_production |
Chlorinator production | equipment | number | % | 0 to 100 |
uv_on |
UV lamp | equipment | bool | ||
plantroom_door |
Plant room door | equipment | enum | open, closed |
|
leak |
Leak | equipment | bool | ||
fault |
Fault | equipment | bool | ||
pump_power |
Pump power | energy | number | W | 0 to 10000 |
heatpump_power |
Heat pump power | energy | number | W | 0 to 50000 |
pump_energy |
Pump energy | energy | counter | kWh | 0 to 10000000 |
heat_energy |
Heat energy | energy | counter | kWh | 0 to 10000000 |
Some quantities accept an equivalent unit through a fixed factor in the catalogue (for example ppm for
mg/l). A key is never renamed or reused. New quantities are added to the catalogue for everyone; ask Lutra.
Reading statuses¶
| Status | Meaning |
|---|---|
ok |
Valid reading |
out_of_range |
Outside the catalogue range; value kept |
invalid |
The device reported a value that is not a valid measurement |
no_flow |
No flow through the measuring cell; value not counted |
comm_error |
Communication error with the device |
no_answer |
The device did not answer |
unknown |
Flow state unknown (no flow switch and the device does not report flow); value not counted |
Two sources may deliver the same quantity for one pool; both are kept, and the cloud chooses per pool which one is shown first.