Remote panel¶
On this page: what the remote panel of a box shows, which settings and commands are available to whom, what the command statuses mean, and how switching works for switching-build boxes. The technical rules are in Remote commands and settings.
What it shows¶
- Firmware version, build (read or switching) and board, and the update channel that fits the box.
- Whether changes from the cloud is enabled on site.
- The telemetry interval and time zone.
- For switching builds: each assigned output with its state, the source of the last change and, if it does not do what was asked, the reason.
- The list of recent commands with their status.
Settings¶
| Setting | Values | Who |
|---|---|---|
| Telemetry interval | 30 to 3600 seconds (default 300) | Administrator, Lutra admin |
| Changes from the cloud | Can only be switched off remotely | Administrator, Lutra admin |
| Time zone | Chosen from the pool's location; firmware 0.2.8 and later | Administrator, Lutra admin |
A change waits until the box confirms it ("waiting for box"). The portal refuses to send a change when:
- the box has not reported recently, so its current state is not known;
- the box changed the setting on site since you loaded the page (the setting's revision differs);
- another change is still waiting;
- the box's firmware does not support revisions (then the portal never writes);
- the new value equals the current one.
The box itself refuses a change that is based on an outdated revision (stale). On site always wins.
Commands¶
Safe commands, for administrators and technicians (technicians with a selection only on their pools):
| Command | What it does |
|---|---|
Diagnosis (get_diag) |
Returns diagnostic information |
Logs (get_logs) |
Returns the last 1 to 200 log lines from a minimum level; firmware 0.2.5 and later |
Bus scan (busscan) |
Scans the RS485 bus for devices; at most once per hour remotely |
Check for update (ota_check) |
Asks the box to fetch and install a signed update. See Updates and channels |
At most 10 commands per box per hour.
| Status | Meaning |
|---|---|
| sent | Sent; waiting for the box |
| executed | The box carried it out, with details |
| refused | The box refused it, with its reason (for example not_supported, not_allowed, stale, replay, signature) |
| no answer | No answer within 60 seconds |
| failed | Signing or sending failed |
Switching outputs¶
Only for boxes running the switching build that report assigned outputs.
- Off is always allowed.
- On requires "changes from the cloud" enabled on site, and the function must allow remote on (refill never does).
- Pump, backwash and heating enable (class B) require an explicit confirmation that you are responsible.
- At most 30 switching commands per box per hour.
- The box applies its interlocks; the reported state shows whether the output really changed and why not.
Administrators and Lutra admin may switch. Technicians switch on site, not through the portal. Owners may switch from their own view only if the administrator allows it for that pool. See Pool owners.
Related pages¶
Last reviewed: 2026-11-24. Applies to Lutra Lite 0.4.1.